Cookie policy: This site uses cookies (small files stored on your computer) to simplify and improve your experience of this website. Cookies are small text files stored on the device you are using to access this website. For more information on how we use and manage cookies please take a look at our privacy and cookie policies. Some parts of the site may not work properly if you choose not to accept cookies.

sections

Data centers to 'Polar Vortex': Bring it on

  • Print
  • Share
  • Comment
  • Save
While most Americans who live in areas of the country affected by this week's extreme temperature drop were caught by surprise, data center operators with facilities in these areas said the so-called “Polar Vortex” did nothing they were unprepared for.
 
Companies that build data centers in these areas design the buildings and the infrastructure to withstand extreme cold weather and have operating procedures in place to double-check preparedness when the temperature does drop.
 
“You prepare for the winter,” David Caron, senior VP of portfolio management at Digital Realty Trust, said. “You have to do it as you design the building.”
 
Weather forecasters on Wednesday said there were signs that the major cold snap that resulted from a region of polar weather breaking off and traveling toward the US was easing. Areas of the country affected the most were the Midwest and the Northeast.
 
Companies design for the climate they are in. A data center in a hurricane-prone area will be designed to withstand strong winds, and a facility in a region that sees a lot of earthquakes will have a number of earthquake-proofing features.
 
“In a market like Chicago you can't be surprised that there's a cold snap,” Caron said.
 
This does not mean that when the temperature drops below 'zero' all data center staff carries on as usual. Corey Needles, senior VP of data center operations at Latisys, which operates a data center in Chicago, said there was a number of things to take into account, especially when the temperature is negative 15F or 20F, as Chicago has seen this week.
 
“We have a subzero check list when it comes to cooling infrastructure,” he said.
 
One of the main things Latisys operations team in Chicago does when cold weather approaches is turn on the redundant free air cooling infrastructure that is located outside of the building. The backup equipment is usually off but when the temperature is below zero, liquid in the piping may freeze if it is not running.
 
There is antifreeze in the liquid, but when it is that cold, the liquid may “slush up,” as Needles put it.
 
Another important check is to make sure no breakers are tripped on the electrical system that powers trace heating along pipes. This is special tape or cabling that runs along the pipes and heats them, commonly used in all kinds of buildings to prevent pipes from freezing and cracking or to maintain constant temperature of liquid running through them.
 
Regular checks of all power systems are done more frequently at Latisys during extreme weather days. Another one of these checks is to make sure dual batteries and heating systems on generators are functioning.
 
Data center operators that bring in outside air for cooling have to be very conscious of humidity levels. Cold air is dry, and data center humidification systems may have groupble keeping up on extremely cold days.
 
At Latisys, operators usually supplement main humidification with small portable humidifiers to address this problem.
 
Another major check, done under any slightly unusual circumstances by data center operators, is emergency communications. CoreSite, another data center operator with presence in Chicago, tests its emergency communication plan on a regular basis, Jarrett Appleby, the company's COO, said.
 
CoreSite's operators also check that adequate supplies, such as diesel fuel, are available, and its security staff increase frequency of outside patrols, since there are fewer people outside during cold weather and there is higher risk of break-ins.

Related images

  • Snow-covered chillers at Latisys' Chicago data center. Courtesy of Latisys

Have your say

Please view our terms and conditions before submitting your comment.

required
required
required
required
required
  • Print
  • Share
  • Comment
  • Save

Webinars

  • Is Hyperconvergence a Viable Alternative to the Public Cloud?

    Thu, 31 Mar 2016 15:00:00

    Enterprise IT leaders are right to be skeptical of such bold claims. After all, is it really possible to deliver an on-premises infrastructure that delivers the same agility, elasticity, and cost-effectiveness of public cloud providers like Amazon Web Services? If you’re following the traditional IT model, with its many siloes and best-of-breed point solutions, the answer is, most likely, no. To truly deliver a viable alternative to public cloud, you need to look beyond traditional IT. Join Evaluator Group and SimpliVity to learn more about how hyperconverged infrastructure can deliver the efficiency, elasticity, and agility of public cloud."

  • "Single Pane of Glass” comes to your Datacenter facility & IT operations

    Wed, 24 Feb 2016 18:00:00

    Join Hewlett Packard Enterprise and RoviSys,as well as OSIsoft, for a webinar hosted by DatacenterDynamics’ CTO Stephen Worn, as they discuss the implementation of the “Single Pane of Glass” solution and some of its resulting benefits: •An estimated 10 Million kWh saved in the first full year of operation •Ability to easily meet “Best-Practices” throughout data center operations

  • Overhead Power Distribution – Best Practice in Modular Design

    Wed, 3 Feb 2016 16:00:00

    Overhead power distribution in your data center offers many attractive possibilities, but is not without its challenges. Join Starline's Director of Marketing, Mark Swift; CPI’s Senior Data Center Consultant, Steve Bornfield; and University of Florida's Joe Keena for an exploration of the options and some of the pitfalls, supported by real-life examples from the field.

  • White Space 29: See the diagram

    Fri, 29 Jan 2016 10:40:00

    Peter is investigating DevOps, Bill looks at security while Max is stuck on the infrastructure level

  • White Space 28: The good, the bad and the ugly

    Thu, 21 Jan 2016 12:10:00

    Join the DCD team again this week, as they discuss AMD's ARM based efforts, waste heat, BT's EU deal and cloud for Canucks and much more! Enjoy.

More link