Cookie policy: This site uses cookies (small files stored on your computer) to simplify and improve your experience of this website. Cookies are small text files stored on the device you are using to access this website. For more information on how we use and manage cookies please take a look at our privacy and cookie policies. Some parts of the site may not work properly if you choose not to accept cookies.

sections

Controlling airflow in the data center

  • Print
  • Share
  • Comment
  • Save

How best to deal with heat generated by high-density equipment and power usage can be cause for concern. Generally, the more kit that can fit into a small space the better, but reaching consensus about how to control temperature involves guesswork. Cold aisle containment is one way to keep dense environments cool and reduce the risk of down time caused by overheating components.

Short airflow paths
Cold aisle containment encloses the cold aisle and prevents the mix of cold air and hot exhaust air. It ensures climate control units keep the airflow path as short as possible – improving the efficiency of the computer room air conditioning system and limiting the energy it demands.

By controlling the air temperature, server components at board level are kept within specified temperature and/or humidity ranges. Cold aisle containment can also be used with inline heat exchangers, so that even higher heat loads per enclosure can be dissipated. The units extract the air from the warm passages then blow it, cooled, into the cold aisle.

In contrast, hot aisle containment allows critical cold air to spread into the general data hall, which can negatively dissipate cooling energy, slowing the effective cooling response and taking longer to reduce server temperature. Cold aisle containment enables a faster cooling response to sudden increases in heat load because the air is not spread into the data hall surroundings but closely contained, directly at the server inlet zone.

Intel has invested in developing its server chips to integrate with third-party cooling systems. Cooling systems are central to any healthy IT system and, while down time should be avoided, the associated cost and how to cut carbon emissions should be considered. 

This is why vertical aisle containment is now being used. It offers a cost-effective, easily maintained solution to air routing and containment for all types of racks by ensuring that the airflow is maintained in the correct direction and at full velocity.

But containing airflow in a vertical direction – with the hot air rising and the cold air falling – can pose a challenge.

If the airflow leaks into adjacent compartments, the efficiency level of a given aisle starts to fall because more energy is required to ensure an adequate airflow is maintained. Manufacturers have carried out onsite testing to help keep energy costs to a minimum and hardware at its optimum temperature.

Live flexibility
Moves, adds and changes to installed equipment in these confined spaces can prove problematic. Free form aisle containment can offer flexibility and the chance to swap out complete racks, in a live, fully operational data center. Structured cabling and airflow system containment are linked to create a single integrated solution that features adjustable vertical closure panels, support for legacy technologies and a low-energy footprint. The technology supports a free-standing aisle infrastructure, and underpins the overhead panels above the aisle without being individually dedicated to any rack.

When carrying out work there is no disturbance to the cold aisle containment infrastructure, which remains in place and functional, and all rack-mounted cable raceway also remains undisturbed. Legacy systems support means that where old rack installations exist, the free form aisle containment technology can offer a cost-effective retrofit aisle cocooning solution

Potential challenges
Configuring a cold aisle containment system for a new data center should be relatively straightforward because it allows specification of uniform products designed to work together. However, there are some issues to note:

- All data center environments evolve and cabinets and racks are no exception with their mix of depths, widths and heights. Cabinets with raised feet for levelling can create a backwash of air underneath them, while there may be gaps either down the sides or where there is missing equipment. Although blanking plates should cover these, they may not be in place, leading to a mix of hot and cold air.

- A retrofitted cold aisle containment system involves fixing the ceiling eyebrow to the top of the cabinets, installing ceiling panels, fitting air skirts under and between the cabinets if necessary, and attaching the doors at both ends of the aisle. This ensures that the cold air emitted from the floor is sealed in a cocoon which is unaffected by hot exhaust air, while the cooling air can only exit through the equipment for which it is intended. It is also likely that the floor will need attention and changes to accommodate the weight of any containment system may also have to be made. Floor tiles can also degrade and break, and replacement tiles may not be the right size.

No air containment system can be effective if there are areas where leaks can occur, so this too will need to be addressed.

 

This article first appeared in FOCUS on Cooling, in Issue 35 of the magazine. To read the full digital edition, click here.

Related images

  • Cold Aisle cooling in a data center

Have your say

Please view our terms and conditions before submitting your comment.

required
required
required
required
required
  • Print
  • Share
  • Comment
  • Save

Webinars

  • Is Hyperconvergence a Viable Alternative to the Public Cloud?

    Thu, 31 Mar 2016 15:00:00

    Enterprise IT leaders are right to be skeptical of such bold claims. After all, is it really possible to deliver an on-premises infrastructure that delivers the same agility, elasticity, and cost-effectiveness of public cloud providers like Amazon Web Services? If you’re following the traditional IT model, with its many siloes and best-of-breed point solutions, the answer is, most likely, no. To truly deliver a viable alternative to public cloud, you need to look beyond traditional IT. Join Evaluator Group and SimpliVity to learn more about how hyperconverged infrastructure can deliver the efficiency, elasticity, and agility of public cloud."

  • "Single Pane of Glass” comes to your Datacenter facility & IT operations

    Wed, 24 Feb 2016 18:00:00

    Join Hewlett Packard Enterprise and RoviSys,as well as OSIsoft, for a webinar hosted by DatacenterDynamics’ CTO Stephen Worn, as they discuss the implementation of the “Single Pane of Glass” solution and some of its resulting benefits: •An estimated 10 Million kWh saved in the first full year of operation •Ability to easily meet “Best-Practices” throughout data center operations

  • Overhead Power Distribution – Best Practice in Modular Design

    Wed, 3 Feb 2016 16:00:00

    Overhead power distribution in your data center offers many attractive possibilities, but is not without its challenges. Join Starline's Director of Marketing, Mark Swift; CPI’s Senior Data Center Consultant, Steve Bornfield; and University of Florida's Joe Keena for an exploration of the options and some of the pitfalls, supported by real-life examples from the field.

  • White Space 29: See the diagram

    Fri, 29 Jan 2016 10:40:00

    Peter is investigating DevOps, Bill looks at security while Max is stuck on the infrastructure level

  • White Space 28: The good, the bad and the ugly

    Thu, 21 Jan 2016 12:10:00

    Join the DCD team again this week, as they discuss AMD's ARM based efforts, waste heat, BT's EU deal and cloud for Canucks and much more! Enjoy.

More link