Cookie policy: This site uses cookies (small files stored on your computer) to simplify and improve your experience of this website. Cookies are small text files stored on the device you are using to access this website. For more information on how we use and manage cookies please take a look at our privacy and cookie policies. Some parts of the site may not work properly if you choose not to accept cookies.

sections

French weather service goes for liquid cooling

  • Print
  • Share
  • Comment
  • Save

France’s national meteorological service Météo-France will boost its supercomputing capabilities in Q1 next year with the help of Bull’s new generation supercomputers – the Bullx B700 DLC.

Bull announced the order, which will see the systems installed its site in Toulouse first then later this year at its Espace Clément Ader facility, today.

It said Météo-France was looking to restrict its electricity consumption and cooling systems for its supercomputers while increasing overall performance.

The new B700 DLC comes with a high performance cooling system and the latest generation of Intel Xeon processors and while it will initially deliver a processing power of about 1 Petaflop this could be ramped up to 5 Petaflops by the end of 2016.

Bull said this increases the usable computing power at the facility by nearly 50%.

This is mostly down to the power and space saving capabilities offered by the direct liquid cooling technology being used by the system, which Bull claims can lower energy use by about a third.

“Cooling takes place inside the blade itself, through direct contact between the heat producing components (processors and memory) and a cold plate with coolant circulating within it,” Bull said.

“This enables water at ambient temperature to be used for cooling, boosting energy performance by around 40% compared to traditional data centers, despite being just as easy to maintain as standard, air-cooled servers.”

The system, according to Bull, makes it possible to cool the data center using incoming water at 35 degrees Celsius.

“It is therefore no longer necessary to produce cold water, which represents considerable savings in terms of electricity consumption, enabling a PUE of 1.1 to be achieved in optimal operating conditions.”

The Bullx cabinet, which supports up to 800kW, contains all the equipment required for cooling, with an electricity supply at top and hydraulic circuits at the bottom.

Météo-France is headquartered in Paris but many of its domestic operations now exist in Toulouse, while the Institute Clement Ader installation is part of a wider initiative with the Météo-France and University of Toulouse Research and Higher Education Center.

Related images

  • Bull is putting its Bullx supercomputer to work for French weather service

Have your say

Please view our terms and conditions before submitting your comment.

required
required
required
required
required
  • Print
  • Share
  • Comment
  • Save

Webinars

  • Live Customer Roundtable: Optimizing Capacity (12:00 EST)

    Tue, 8 Sep 2015 16:00:00

    The biggest challenge facing many data centers today? Capacity. How to optimize what you have today. And when you need to expand, how to expand your capacity smarter. Learn from the experts about how Data Center Infrastructure Management (DCIM) and Prefabricated Modular Data Centers are driving best practices in how capacity is managed and optimized: - lower costs - improved efficiencies and performance - better IT services delivered to the business - accurate long-range planning Don;t miss out on our LIVE customer roundtable and your chance to pose questions to expert speakers from Commscope, VIRTUS and University of Montana. These enterprises are putting best practices to work today in the only place that counts – the real world.

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (APAC)

    Wed, 26 Aug 2015 05:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (Americas)

    Tue, 25 Aug 2015 18:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (EMEA)

    Tue, 25 Aug 2015 14:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • 5 Reasons Why DCIM Has Failed

    Wed, 15 Jul 2015 10:00:00

    Historically, DCIM systems have over-promised and under-delivered. Vendors have supplied complex and costly solutions which fail to address real business drivers and goals. Yet the rewards can be vast and go well beyond better-informed decision-making, to facilitate continuous improvement and cost savings across the infrastructure. How can vendors, customers and the industry as a whole take a better approach? Find out on our webinar on Wednesday 15 July.

More link