Cookie policy: This site uses cookies (small files stored on your computer) to simplify and improve your experience of this website. Cookies are small text files stored on the device you are using to access this website. For more information on how we use and manage cookies please take a look at our privacy and cookie policies. Some parts of the site may not work properly if you choose not to accept cookies.

sections

Cummins claims "unprecendented" safety rating for switches

  • Print
  • Share
  • Comment
  • Save

Minneapolis based Cummins Power Generation's transfer switches received unprecedented "withstand and closing" ratings from a U.S. product safety testing and certification company after being tested for their ability to surive sever levels of short circuit, the company said.

The open transition and closed transition switches demonstrated short-time ratings of 25 kA at 10 cycles for 125- to 260-amp switches, 30 kA at 30 cycles for 300 to 600 amps, and 50 kA at 30 cycles for 800-amp switches in tests designed by Underwriters Laboratories.

After testing, the switches operated at full load safely.

"They were undamaged," Cummins Director of Power System Development Gary Olson said. "They could take the short circuit, conditioned for 30 cycles... (and) still carry rated load."

The product was designed for use in data centers, banks, government office buildings, as well as in hospitals and emergency shelters. It is not however, appropriate for large data centers.

"This would probably suit more mid- to smaller-size data centers," Olson said.

The UL rating validates the product in the eyes of engineers as an "independent assurance" of its high performance level, according to a Cummins statement.

Specifying transfer switches' UL ratings also helps engineers with selective coordination, the process of selecting circuit breakers and transfer switches with a combination of timing and withstand parameters that allows for localization of an overcurrent condition by delaying or preventing current faults from tripping upstream protection devices.

"As he's designing protection for his system, (an engineer) wants to make sure that (in case of a fault), the only breaker that trips is the closest upstream to the fault," Olson explained.

With a transfer switch capable of withstanding fault current for up to 30 cycles, the engineer can adjust time delay on the overcurrent protection device to prevent upstream breakers from tripping unnecessarily.

The U.S. National Electrical Code can require selective coordination in electrical systems of data centers, banks, government offices, hospitals and emergency shelters.

Have your say

Please view our terms and conditions before submitting your comment.

required
required
required
required
required
  • Print
  • Share
  • Comment
  • Save

Webinars

  • Live Customer Roundtable: Optimizing Capacity (12:00 EST)

    Tue, 8 Sep 2015 16:00:00

    The biggest challenge facing many data centers today? Capacity. How to optimize what you have today. And when you need to expand, how to expand your capacity smarter. Learn from the experts about how Data Center Infrastructure Management (DCIM) and Prefabricated Modular Data Centers are driving best practices in how capacity is managed and optimized: - lower costs - improved efficiencies and performance - better IT services delivered to the business - accurate long-range planning Don;t miss out on our LIVE customer roundtable and your chance to pose questions to expert speakers from Commscope, VIRTUS and University of Montana. These enterprises are putting best practices to work today in the only place that counts – the real world.

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (APAC)

    Wed, 26 Aug 2015 05:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (Americas)

    Tue, 25 Aug 2015 18:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • Power Optimization – Can Your Business Survive an Unplanned Outage? (EMEA)

    Tue, 25 Aug 2015 14:00:00

    Most outages are accidental; by adopting an intelligent power chain, you can help mitigate them and reduce your mean-time to repair. Join Anixter and DatacenterDynamics for a webinar on the five best practices and measurement techniques to help you obtain the performance data you need to optimize your power chain. Register today!

  • 5 Reasons Why DCIM Has Failed

    Wed, 15 Jul 2015 10:00:00

    Historically, DCIM systems have over-promised and under-delivered. Vendors have supplied complex and costly solutions which fail to address real business drivers and goals. Yet the rewards can be vast and go well beyond better-informed decision-making, to facilitate continuous improvement and cost savings across the infrastructure. How can vendors, customers and the industry as a whole take a better approach? Find out on our webinar on Wednesday 15 July.

More link